| Analytical
Services |
 |
|
| |
|
The Sophisticated Analytical
Instrument Facility has several highly sophisticated
and modern analytical equipment. Analytical
services are offered to both internal and
external users. The facilities are availed
by about 250 internal users and 500 external
users annually. More than 80% of the external
users comprise researchers from universities
and colleges. Researchers from national
laboratories and industries constitute the
rest. Some of the major facilities being
provided are: |
| |
|
|
Mass spectrometry |
|
|
NMR spectrometry |
|
|
Routine facilities such
as IR/UV, GLC |
|
| |
| Service to the outside users
is provided on payment basis. The samples
required for test also vary have to be sent
as per the requirement of the analysis. |
| |
| Charges
for the Analytical Services and the requirement
of test Sample |
| |
|
Service Charges * |
|
S.No. |
Facility |
Requirements
on test sample |
Charges in
Rs./ hr./ sample / spectrum Service Tax (12.36%) will be extra |
|
1. |
Mass Spectrometers
Jeol SX-102 (FAB)
Micromass Quattro II
(APCI, ESI, LCMS,
MS/MS
Shimadzu QP-2000
(GC/MS)
Micromass TofSpec 2E
MALDI TOF MS
JEOL Accutof -DARTMS |
1 - 2 mg
Nature of the sample, melting point, solubility, elements present, expected m.wt & structure, GC conditions and GC trace for GC/MS, LC conditions & LC trace for LCMS. ESI MS is possible only in methanol, acetonitrile or water.
|
1500/-
per hr. or part thereof with a minimum of Rs. 1500/- per sample for additional facilities such as negative ion, FAB, APCI, ESI, LC/MS & MS/MS, MALDI TOF MS, DARTMS
1000/- per hr or part thereof for GCMS. |
|
2. |
NMR Spectrometers
Bruker DRX-300
(300 MHz FT NMR with low and high temperature facility
-90°C to +80 °C)
Bruker Avance 400
(400 MHz FT NMR with, 5 mm multi-nuclear inverse probe head, low and high temperature facility and HRMAS accessory) |
2-4 mg for 1H NMR & 30-40 mg for 13C NMR experiment
Nature of compound, e.g., carcinogenic, radio active, solubility, lachrymatory, explosive, hygroscopic etc., structural formula (contemplated/known). Required amount of sample must be soluble in 0.5-0.6 ml of deuterated solvent.
2-4 mg for 1HNMR and 30-40 mg for inverse 2D experiments (X-H). Rest same as above. 13C, 31P etc spectra can also be recorded but with lesser sensitivity.
For HRMAS measurements 100-500 μg sample must be soluble in 12-50 μl of solvent for 1HNMR, 2 mg soluble in 50 μl of solvent for 13C or inverse 2D experiments (1H-13C). Gel NMR measurement as well as resin bound molecules NMR measurement can be carried out |
1000/- for each half hr. or less
100/- solvent charges extra for deuterated solvents other than CDCl3 and D2O. |
|
3. |
FT IR
Spectrophotometers
Shimadzu 8201 PC
(4000-400 cm-1)
Perkin Elmer
Spectrum RX1
(4000-450 cm-1) |
5-10 mg
KBr/Nujol/CsI/CHCl3, nature (hygroscopic, explosive etc.)
-do- |
500/-
per spectrum per samples |
|
4. |
Gas Liquid
Chromatograph
Perkin Elmer
Autosystem XL |
2-5 mg
Nature of compound, solubility, melting point/ boiling point, column (if known) |
500/-
per hr. per sample |
|
5. |
Elemental Analyzers
Elementar Vario EL III
Carlo Erba 1108 |
10
mg
other elements present,
approximate % of nitrogen |
400/-
per element per sample
(CHNS&O) |
|
6. |
Polarimeter
Rudolf Autopol III |
20
mg
sample should be completely
soluble in the suggested solvent &free
from foreign particles |
400/-
per sample |
|
* Charges
given are for Private Industries
National Laboratries and Private & Government
Small Scale Industries will pay 3/5th of these
charges;
** Fixed charge- same for all.
|
| |
| Note
: |
|
As per Govt. rules Service Tax (12.36%) will be charged on the analysis charges. |
|
|
The analytical data/spectra are provided only for research/ development purposes. These can not be used as certificates in legal disputes. |
|
|
Service charges are payable in advance by crossed bank draft in favour of the Director, Central Drug Research Institute, Lucknow-226001. |
|
|
Samples and payment should be sent preferably in the same cover. Separate samples should be sent for different analysis. Samples are not analysed till payment is received. |
|
|
Maximum 5 samples for Mass, 5 samples for 13C, 19F, 31P NMR and 10 samples for other types of analysis are accepted at a time. |
|
|
Please send the samples in quantity as mentioned in the brochure. Samples are not recovered unless a special request is made. |
|
|
In all correspondence related to analysis our reference number must be mentioned. |
|
|
Radio -active material
should be clearly mentioned and handed
over personally. |
|
|
Unstable and explosive
compounds are not accepted for analysis. |
|
|
Services are rendered to only those users who regularly give us feed-back about the end-use of the results, e.g., thesis, patent, process, publication etc. |
|
|
Research fellows and students are advised to send their application and samples through their Supervisor or Head of Department. The request should be on University / College / Institute letter head. |
|
|
Interpretation of spectra is not undertaken normally. In special cases this service can be provided on payment of extra charges. |
|
| |
All
Communication should be addressed to
Head
Sophisticated analytical Instrument Facility,
Central Drug Research Institute,
Post Box No.173,
Lucknow 226001 |
|
|
|
|
| |
|
website
copyright © Central Drug Research Institute.
All rights reserved.
No part of this should be Downloaded or used
in any way other than the non-commercial purposes
without prior permission of the Director,
CDRI. |
|
|
|
 |
| Powered
by MARG Software Solutions |
Contact
us |
You
are Visitor No. |
| Best viewed
at 800 X 600 Resolutions | Internet
Explorer 5.0 - Later Version |
<%
if session("iNumber")="" then
'conn.open mydsn
Dim rsHits
Set rsHits=Server.CreateObject("ADODB.Recordset")
rsHits.CursorLocation=adUseClient
rsHits.Open "Select visits from Hits", conn, adOpenKeyset, adLockOptimistic
session("iNumber")=rsHits("visits") + 1
rsHits("visits")=rsHits("visits") + 1
rsHits.Update
rsHits.Close
set rsHits=Nothing
end if
If Len(session("iNumber")) > 0 then
'Display iNumber
Response.Write "" & ConstructDigits(session("iNumber")) & ""
End If
''''
Function ConstructDigits(iValue)
'This function accepts a single parameter, iValue, and
'returns HTML containing a series of images representing
'a graphical image of the value in iValue
'Start by ensuring iValue is a number
If Not IsNumeric(iValue) then
ConstructDigits = iValue & " IS NOT A NUMBER!"
Exit Function
End If
'Can't show decimals!
If InStr(1, iValue, ".") then
ConstructDigits = "CANNOT CONTAIN DECIMALS!"
Exit Function
End If
'Can't show negative numbers!
If iValue < 0 then
ConstructDigits = "CANNOT DISPLAY NEGATIVE NUMBERS!"
Exit Function
End If
Dim iLoop, strResults
For iLoop = (Len(iValue) - 1) to 0 STEP -1
strResults = strResults & ""
Next
ConstructDigits = strResults
End Function
''''
%>
|
|
|
|
|
|